SFLOW-MIB DEFINITIONS ::= BEGIN

IMPORTS
	MODULE-IDENTITY,
	OBJECT-TYPE,
	Integer32,
	enterprises
		FROM SNMPv2-SMI
	SnmpAdminString
		FROM SNMP-FRAMEWORK-MIB
	OwnerString
		FROM RMON-MIB
	InetAddressType,
	InetAddress
		FROM INET-ADDRESS-MIB
	MODULE-COMPLIANCE,
	OBJECT-GROUP
		FROM SNMPv2-CONF;

sFlowMIB MODULE-IDENTITY
	LAST-UPDATED "200105150000Z"	-- May 15, 2001 12:00:00 AM
	ORGANIZATION "InMon Corp."
	CONTACT-INFO
		"Peter Phaal
		InMon Corp.
		http://www.inmon.com/

		Tel:  +1-415-661-6343
		Email: peter_phaal@inmon.com"
	DESCRIPTION
		"The MIB module for managing the generation and transportation
		of sFlow data records."
	REVISION "200105150000Z"	-- May 15, 2001 12:00:00 AM
	DESCRIPTION
		"Version 1.2

		Brings MIB into SMI v2 compliance."
	REVISION "200105010000Z"	-- May 1, 2001 12:00:00 AM
	DESCRIPTION
		"Version 1.1

		Adds sFlowDatagramVersion."
	-- 1.3.6.1.4.1.4300.1
	::= { enterprises 4300 1 }


sFlowAgent OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.4300.1.1
	::= { sFlowMIB 1 }

sFlowVersion OBJECT-TYPE
	SYNTAX  SnmpAdminString
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"Uniquely identifies the version and implementation of this MIB.
		The version string must have the following structure:
		   <MIB Version>;<Organization>;<Software Revision>
		where:
		   <MIB Version>  must be '1.2', the version of this MIB.
		   <Organization> the name of the organization responsible
		                    for the agent implementation.
		   <Revision>     the specific software build of this agent.

		As an example, the string '1.2;InMon Corp.;2.1.1' indicates
		that this agent implements version '1.2' of the SFLOW MIB, that
		it was developed by 'InMon Corp.' and that the software build
		is '2.1.1'.

		The MIB Version will change with each revision of the SFLOW





		MIB.

		Management entities must check the MIB Version and not attempt
		to manage agents with MIB Versions greater than that for which
		they were designed.

		Note: The sFlow Datagram Format has an independent version
		      number which may change independently from <MIB Version>.
		      <MIB Version> applies to the structure and semantics of
		      the SFLOW MIB only."
	DEFVAL { "1.2;;" }
	-- 1.3.6.1.4.1.4300.1.1.1
	::= { sFlowAgent 1 }


sFlowAgentAddressType OBJECT-TYPE
	SYNTAX  InetAddressType
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"The address type of the address associated with this agent.
		Only ipv4 and ipv6 types are supported."
	-- 1.3.6.1.4.1.4300.1.1.2
	::= { sFlowAgent 2 }


sFlowAgentAddress OBJECT-TYPE
	SYNTAX  InetAddress
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"The IP address associated with this agent.  In the case of a
		multi-homed agent, this should be the loopback address of the
		agent.  The sFlowAgent address must provide SNMP connectivity
		to the agent.  The address should be an invariant that does not
		change as interfaces are reconfigured, enabled, disabled,
		added or removed.  A manager should be able to use the
		sFlowAgentAddress as a unique key that will identify this
		agent over extended periods of time so that a history can
		be maintained."
	-- 1.3.6.1.4.1.4300.1.1.3
	::= { sFlowAgent 3 }


sFlowTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF SFlowEntry
	MAX-ACCESS not-accessible
	STATUS  current
	DESCRIPTION
		"A table of the sFlow samplers within a device."
	-- 1.3.6.1.4.1.4300.1.1.4
	::= { sFlowAgent 4 }


sFlowEntry OBJECT-TYPE
	SYNTAX  SFlowEntry
	MAX-ACCESS not-accessible
	STATUS  current
	DESCRIPTION
		"Attributes of an sFlow sampler."
	INDEX {
		sFlowDataSource }
	-- 1.3.6.1.4.1.4300.1.1.4.1
	::= { sFlowTable 1 }


SFlowEntry ::= SEQUENCE {

	sFlowDataSource              OBJECT IDENTIFIER,
	sFlowOwner                   OwnerString,
	sFlowTimeout                 Integer32,
	sFlowPacketSamplingRate      Integer32,
	sFlowCounterSamplingInterval Integer32,
	sFlowMaximumHeaderSize       Integer32,
	sFlowMaximumDatagramSize     Integer32,
	sFlowCollectorAddressType    InetAddressType,
	sFlowCollectorAddress        InetAddress,
	sFlowCollectorPort           Integer32,
	sFlowDatagramVersion         Integer32 }


sFlowDataSource OBJECT-TYPE
	SYNTAX  OBJECT IDENTIFIER
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"Identifies the source of the data for the sFlow sampler.
		The following data source types are currently defined:

		- ifIndex.<I>
		DataSources of this traditional form are called 'port-based'.
		Ideally the sampling entity will perform sampling on all flows
		originating from or destined to the specified interface.
		However, if the switch architecture only permits input or
		output sampling then the sampling agent is permitted to only
		sample input flows input or output flows.  Each packet must
		only be considered once for sampling, irrespective of the
		number of ports it will be forwarded to.

		Note: Port 0 is used to indicate that all ports on the device
		      are represented by a single data source.
		      - sFlowPacketSamplingRate applies to all ports on the
		        device capable of packet sampling.
		      - sFlowCounterSamplingInterval applies to all ports.

		- smonVlanDataSource.<V>
		A dataSource of this form refers to a 'Packet-based VLAN'
		and is called a 'VLAN-based' dataSource.  <V> is the VLAN





		ID as defined by the IEEE 802.1Q standard.  The
		value is between 1 and 4094 inclusive, and it represents
		an 802.1Q VLAN-ID with global scope within a given
		bridged domain.
		Sampling is performed on all packets received that are part
		of the specified VLAN (no matter which port they arrived on).
		Each packet will only be considered once for sampling,
		irrespective of the number of ports it will be forwarded to.

		- entPhysicalEntry.<N>
		A dataSource of this form refers to a physical entity within
		the agent (e.g., entPhysicalClass = backplane(4)) and is called
		an 'entity-based' dataSource.
		Sampling is performed on all packets entering the resource (e.g.
		If the backplane is being sampled, all packets transmitted onto
		the backplane will be considered as single candidates for
		sampling irrespective of the number of ports they ultimately
		reach).

		Note: Since each DataSource operates independently, a packet
		      that crosses multiple DataSources may generate multiple
		      flow records."
	-- 1.3.6.1.4.1.4300.1.1.4.1.1
	::= { sFlowEntry 1 }


sFlowOwner OBJECT-TYPE
	SYNTAX  OwnerString
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"The entity making use of this sFlow sampler.  The empty string
		indicates that the sFlow sampler is currently unclaimed.
		An entity wishing to claim an sFlow sampler must make sure
		that the sampler is unclaimed before trying to claim it.
		The sampler is claimed by setting the owner string to identify
		the entity claiming the sampler.  The sampler must be claimed
		before any changes can be made to other sampler objects.

		In order to avoid a race condition, the entity taking control
		of the sampler must set both the owner and a value for
		sFlowTimeout in the same SNMP set request.

		When a management entity is finished using the sampler,
		it should set its value back to unclaimed.  The agent
		must restore all other entities this row to their
		default values when the owner is set to unclaimed.

		This mechanism provides no enforcement and relies on the
		cooperation of management entities in order to ensure that





		competition for a sampler is fairly resolved."
	DEFVAL { "" }
	-- 1.3.6.1.4.1.4300.1.1.4.1.2
	::= { sFlowEntry 2 }


sFlowTimeout OBJECT-TYPE
	SYNTAX  Integer32
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"The time (in seconds) remaining before the sampler is released
		and stops sampling.  When set, the owner establishes control
		for the specified period.  When read, the remaining time in the
		interval is returned.

		A management entity wanting to maintain control of the sampler
		is responsible for setting a new value before the old one
		expires.

		When the interval expires, the agent is responsible for
		restoring all other entities in this row to their default
		values."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.4300.1.1.4.1.3
	::= { sFlowEntry 3 }


sFlowPacketSamplingRate OBJECT-TYPE
	SYNTAX  Integer32
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"The statistical sampling rate for packet sampling from this
		source.

		Set to N to sample 1/Nth of the packets in the monitored flows.
		An agent should choose its own algorithm introduce variance
		into the sampling so that exactly every Nth packet is not
		counted.  A sampling rate of 1 counts all packets.  A sampling
		rate of 0 disables sampling.

		The agent is permitted to have minimum and maximum allowable
		values for the sampling rate.  A minimum rate lets the agent
		designer set an upper bound on the overhead associated with
		sampling, and a maximum rate may be the result of hardware
		restrictions (such as counter size).  In addition not all values
		between the maximum and minimum may be realizable as the
		sampling rate (again because of implementation considerations).

		When the sampling rate is set the agent is free to adjust the
		value so that it lies between the maximum and minimum values





		and has the closest achievable value.

		When read, the agent must return the actual sampling rate it
		will be using (after the adjustments previously described).  The
		sampling algorithm must converge so that over time the number
		of packets sampled approaches 1/Nth of the total number of
		packets in the monitored flows."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.4300.1.1.4.1.4
	::= { sFlowEntry 4 }


sFlowCounterSamplingInterval OBJECT-TYPE
	SYNTAX  Integer32
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"The maximum number of seconds between successive samples of the
		counters associated with this data source.  A sampling interval
		of 0 disables counter sampling."
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.4300.1.1.4.1.5
	::= { sFlowEntry 5 }


sFlowMaximumHeaderSize OBJECT-TYPE
	SYNTAX  Integer32
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"The maximum number of bytes that should be copied from a
		sampled packet.  The agent may have an internal maximum and
		minimum permissible sizes.  If an attempt is made to set this
		value outside the permissible range then the agent should
		adjust the value to the closest permissible value."
	DEFVAL { 128 }
	-- 1.3.6.1.4.1.4300.1.1.4.1.6
	::= { sFlowEntry 6 }


sFlowMaximumDatagramSize OBJECT-TYPE
	SYNTAX  Integer32
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"The maximum number of data bytes that can be sent in a single
		sample datagram.  The manager should set this value to avoid
		fragmentation of the sFlow datagrams."
	DEFVAL { 1400 }
	-- 1.3.6.1.4.1.4300.1.1.4.1.7
	::= { sFlowEntry 7 }


sFlowCollectorAddressType OBJECT-TYPE
	SYNTAX  InetAddressType
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"The type of sFlowCollectorAddress."
	DEFVAL { ipv4 }
	-- 1.3.6.1.4.1.4300.1.1.4.1.8
	::= { sFlowEntry 8 }


sFlowCollectorAddress OBJECT-TYPE
	SYNTAX  InetAddress
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"The IP address of the sFlow collector.
		If set to 0.0.0.0 all sampling is disabled."
	DEFVAL { "0.0.0.0" }
	-- 1.3.6.1.4.1.4300.1.1.4.1.9
	::= { sFlowEntry 9 }


sFlowCollectorPort OBJECT-TYPE
	SYNTAX  Integer32
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"The destination port for sFlow datagrams."
	DEFVAL { 6343 }
	-- 1.3.6.1.4.1.4300.1.1.4.1.10
	::= { sFlowEntry 10 }


sFlowDatagramVersion OBJECT-TYPE
	SYNTAX  Integer32
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"The version of sFlow datagrams that should be sent.

		When set to a value not support by the agent, the agent should
		adjust the value to the highest supported value less than the
		requested value, or return an error if no such values exist."
	DEFVAL { 4 }
	-- 1.3.6.1.4.1.4300.1.1.4.1.11
	::= { sFlowEntry 11 }


--
-- Compliance Statements
--

sFlowMIBConformance OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.4300.1.2
	::= { sFlowMIB 2 }

sFlowMIBGroups OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.4300.1.2.1
	::= { sFlowMIBConformance 1 }

sFlowMIBCompliances OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.4300.1.2.2
	::= { sFlowMIBConformance 2 }


sFlowCompliance MODULE-COMPLIANCE
	STATUS  current
	DESCRIPTION
		"Compliance statements for the sFlow Agent."

	MODULE 
	MANDATORY-GROUPS {
			sFlowAgentGroup }

	OBJECT sFlowAgentAddressType
	  SYNTAX InetAddressType {
			ipv4(1) }
	  DESCRIPTION 
		"Agents need only support ipv4."
	OBJECT sFlowCollectorAddressType
	  SYNTAX InetAddressType {
			ipv4(1) }
	  DESCRIPTION 
		"Agents need only support ipv4."
	-- 1.3.6.1.4.1.4300.1.2.2.1
	::= { sFlowMIBCompliances 1 }

sFlowAgentGroup OBJECT-GROUP
	OBJECTS {
		sFlowVersion,
		sFlowAgentAddressType,
		sFlowAgentAddress,
		sFlowDataSource,
		sFlowOwner,
		sFlowTimeout,
		sFlowPacketSamplingRate,
		sFlowCounterSamplingInterval,
		sFlowMaximumHeaderSize,
		sFlowMaximumDatagramSize,
		sFlowCollectorAddressType,
		sFlowCollectorAddress,
		sFlowCollectorPort,
		sFlowDatagramVersion }
	STATUS  current
	DESCRIPTION
		"A collection of objects for managing the generation and
		transportation of sFlow data records."
	-- 1.3.6.1.4.1.4300.1.2.1.1
	::= { sFlowMIBGroups 1 }

END