MPLS-OAM-ID-STD-MIB DEFINITIONS ::= BEGIN


       IMPORTS
          MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
          Unsigned32
             FROM SNMPv2-SMI                   -- RFC 2578
          MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
             FROM SNMPv2-CONF                  -- RFC 2580
          RowStatus, RowPointer, StorageType
             FROM SNMPv2-TC                    -- RFC 2579
          SnmpAdminString
             FROM SNMP-FRAMEWORK-MIB           -- RFC 3411
          IndexIntegerNextFree
             FROM DIFFSERV-MIB                 -- RFC 3289
          mplsStdMIB
             FROM MPLS-TC-STD-MIB              -- RFC 3811
          InterfaceIndexOrZero, ifGeneralInformationGroup,
          ifCounterDiscontinuityGroup
             FROM IF-MIB;                      -- RFC 2863

      mplsOamIdStdMIB MODULE-IDENTITY
         LAST-UPDATED
            "201601070000Z" -- January 07, 2016
         ORGANIZATION
            "Multiprotocol Label Switching (MPLS) Working Group"
         CONTACT-INFO
            "Sam Aldrin
             Google, Inc.
             1600 Amphitheatre Parkway
             Mountain View, CA  94043
             USA
             Email: aldrin.ietf@gmail.com

             Thomas D. Nadeau
             Email: tnadeau@lucidvision.com

             Venkatesan Mahalingam
             Dell, Inc.
             5450 Great America Parkway
             Santa Clara, CA  95054
             USA
             Email: venkat.mahalingams@gmail.com









             Kannan KV Sampath
             Redeem
             India
             Email: kannankvs@gmail.com

             Ping Pan
             Infinera

             Sami Boutros
             VMware, Inc.
             3401 Hillview Ave.
             Palo Alto, CA  94304
             USA
             Email: sboutros@vmware.com"

         DESCRIPTION
            "Copyright (c) 2016 IETF Trust and the persons identified
             as authors of the code.  All rights reserved.

             Redistribution and use in source and binary forms, with or
             without modification, is permitted pursuant to, and subject
             to the license terms contained in, the Simplified BSD
             License set forth in Section 4.c of the IETF Trust's
             Legal Provisions Relating to IETF Documents
             (http://trustee.ietf.org/license-info).

             This MIB module contains generic object definitions for
             MPLS OAM identifiers."

         -- Revision history

         REVISION
            "201601070000Z" -- January 07, 2016
         DESCRIPTION
            "MPLS OAM Identifiers MIB objects for Tunnels, LSPs,
             Pseudowires, and Sections."

         ::= { mplsStdMIB 21 }

      -- Top-level components of this MIB module

      -- notifications
      mplsOamIdNotifications
                   OBJECT IDENTIFIER ::= { mplsOamIdStdMIB 0 }
      -- tables, scalars
      mplsOamIdObjects  OBJECT IDENTIFIER ::= { mplsOamIdStdMIB 1 }







      -- conformance
      mplsOamIdConformance
                   OBJECT IDENTIFIER ::= { mplsOamIdStdMIB 2 }

       -- Start of MPLS Transport Profile MEG table

      mplsOamIdMegIndexNext OBJECT-TYPE
         SYNTAX        IndexIntegerNextFree (0..4294967295)
         MAX-ACCESS    read-only
         STATUS        current
         DESCRIPTION
           "This object contains an unused value for
            mplsOamIdMegIndex, or a zero to indicate
            that none exist.  Negative values are not allowed,
            as they do not correspond to valid values of
            mplsOamIdMegIndex."
         ::= { mplsOamIdObjects 1 }

      mplsOamIdMegTable OBJECT-TYPE
         SYNTAX        SEQUENCE OF MplsOamIdMegEntry
         MAX-ACCESS    not-accessible
         STATUS        current
         DESCRIPTION
           "This table contains information about the Maintenance
            Entity Groups (MEGs).

            A MEG, as mentioned in the MPLS-TP OAM framework, defines
            a set of one or more Maintenance Entities (MEs).
            MEs define a relationship between any two points of a
            transport path in an OAM domain to which maintenance and
            monitoring operations apply."
         ::= { mplsOamIdObjects 2 }

       mplsOamIdMegEntry OBJECT-TYPE
          SYNTAX        MplsOamIdMegEntry
          MAX-ACCESS    not-accessible
          STATUS        current
          DESCRIPTION
            "An entry in this table represents an MPLS-TP MEG.
             An entry can be created by a network administrator
             or by an SNMP agent as instructed by an MPLS-TP OAM
             framework.

             When a new entry is created with
             mplsOamIdMegOperatorType set to ipCompatible (1),
             then as per RFC 6370 (MEG_ID for an LSP is LSP_ID, and
             MEG_ID for a PW is PW_Path_ID), MEP_ID can be
             automatically formed.





             For a co-routed bidirectional LSP, MEG_ID is
             A1-{Global_ID::Node_ID::Tunnel_Num}::Z9-{Global_ID::
             Node_ID::Tunnel_Num}::LSP_Num.

             For an associated bidirectional LSP, MEG_ID is
             A1-{Global_ID::Node_ID::Tunnel_Num::LSP_Num}::
             Z9-{Global_ID::Node_ID::Tunnel_Num::LSP_Num}.

             For an LSP, MEP_ID is formed using
             Global_ID::Node_ID::Tunnel_Num::LSP_Num.

             For a PW, MEG_ID is formed using AGI::
             A1-{Global_ID::Node_ID::AC_ID}::
             Z9-{Global_ID::Node_ID::AC_ID}.

             For a PW, MEP_ID is formed using
             AGI::Global_ID::Node_ID::AC_ID.

             MEP_ID is retrieved from the mplsOamIdMegServicePointer
             object based on the mplsOamIdMegServicePointerType value.
             The ICC MEG_ID for an LSP and a PW is formed using the
             objects mplsOamIdMegIdIcc and mplsOamIdMegIdUmc.

             MEP_ID can be formed using MEG_ID::MEP_Index."
          REFERENCE
            "1. RFC 5860: Requirements for Operations, Administration,
                and Maintenance (OAM) in MPLS Transport Networks,
                May 2010.
             2. RFC 6371: Operations, Administration, and Maintenance
                Framework for MPLS-Based Transport Networks,
                September 2011, Section 3.
             3. RFC 6370: MPLS Transport Profile (MPLS-TP) Identifiers,
                September 2011.
             4. RFC 6923: MPLS Transport Profile (MPLS-TP) Identifiers
                Following ITU-T Conventions, May 2013."
          INDEX { mplsOamIdMegIndex }
          ::= { mplsOamIdMegTable 1 }
















          MplsOamIdMegEntry ::= SEQUENCE {
             mplsOamIdMegIndex                 Unsigned32,
             mplsOamIdMegName                  SnmpAdminString,
             mplsOamIdMegOperatorType          INTEGER,
             mplsOamIdMegIdCc                  SnmpAdminString,
             mplsOamIdMegIdIcc                 SnmpAdminString,
             mplsOamIdMegIdUmc                 SnmpAdminString,
             mplsOamIdMegServicePointerType    INTEGER,
             mplsOamIdMegMpLocation            INTEGER,
             mplsOamIdMegPathFlow              INTEGER,
             mplsOamIdMegOperStatus            INTEGER,
             mplsOamIdMegSubOperStatus         BITS,
             mplsOamIdMegRowStatus             RowStatus,
             mplsOamIdMegStorageType           StorageType
       }

       mplsOamIdMegIndex  OBJECT-TYPE
          SYNTAX        Unsigned32 (1..4294967295)
          MAX-ACCESS    not-accessible
          STATUS        current
          DESCRIPTION
            "Index for the conceptual row identifying a MEG within
             this MEG table.  Managers should obtain new values for row
             creation in this table by reading mplsOamIdMegIndexNext."
          ::= { mplsOamIdMegEntry 1 }

       mplsOamIdMegName  OBJECT-TYPE
          SYNTAX        SnmpAdminString (SIZE(0..48))
          MAX-ACCESS    read-create
          STATUS        current
          DESCRIPTION
            "Each MEG has a unique name amongst all those used or
             available to a service provider or operator.  It
             facilitates easy identification of administrative
             responsibility for each MEG."
          ::= { mplsOamIdMegEntry 2 }

















       mplsOamIdMegOperatorType OBJECT-TYPE
          SYNTAX        INTEGER {
                            ipCompatible (1),
                            iccBased (2)
                        }
          MAX-ACCESS    read-create
          STATUS        current
          DESCRIPTION
            "Indicates the operator type for the MEG.  Conceptual rows
             having 'iccBased' as the operator type MUST have valid
             values for the objects mplsOamIdMegIdIcc and
             mplsOamIdMegIdUmc when the row status is active."
          REFERENCE
            "1. RFC 6370: MPLS Transport Profile (MPLS-TP) Identifiers,
                September 2011.
             2. RFC 6923: MPLS Transport Profile (MPLS-TP) Identifiers
                Following ITU-T Conventions, May 2013, Section 3.1."
          DEFVAL { ipCompatible }
          ::= { mplsOamIdMegEntry 3 }

       mplsOamIdMegIdCc OBJECT-TYPE
          SYNTAX        SnmpAdminString (SIZE(0..2))
          MAX-ACCESS    read-create
          STATUS        current
          DESCRIPTION
            "Global uniqueness is assured by concatenating the ICC
             with a Country Code (CC).  The Country Code (alpha-2)
             is a string of two alphabetic characters represented
             with uppercase letters (i.e., A-Z).

             This object MUST contain a non-null value if
             the MplsOamIdMegOperatorType value is iccBased (2);
             otherwise, a null value with octet size 0
             should be assigned."
          REFERENCE
            "RFC 6923: MPLS Transport Profile (MPLS-TP) Identifiers
             Following ITU-T Conventions, May 2013, Section 3."
          DEFVAL {""}
          ::= { mplsOamIdMegEntry 4 }














       mplsOamIdMegIdIcc OBJECT-TYPE
          SYNTAX        SnmpAdminString (SIZE(0..6))
          MAX-ACCESS    read-create
          STATUS        current
          DESCRIPTION
            "Unique code assigned to a network operator or service
             provider; maintained by the ITU-T.  This is the
             ITU Carrier Code used to form the MEGID.

             This object MUST contain a non-null value if
             the MplsOamIdMegOperatorType value is iccBased (2);
             otherwise, a null value with octet size 0
             should be assigned."
          REFERENCE
            "RFC 6923: MPLS Transport Profile (MPLS-TP) Identifiers
             Following ITU-T Conventions, May 2013, Section 3.1."
          DEFVAL {""}
          ::= { mplsOamIdMegEntry 5 }

       mplsOamIdMegIdUmc OBJECT-TYPE
          SYNTAX        SnmpAdminString (SIZE(0..7))
          MAX-ACCESS    read-create
          STATUS        current
          DESCRIPTION
            "Unique code assigned by a network operator or service
             provider.  This code is appended to mplsOamIdMegIdIcc to
             form the MEGID.
             This object MUST contain a non-null value if
             the MplsOamIdMegOperatorType value is iccBased (2);
             otherwise, a null value with octet size 0
             should be assigned."
          REFERENCE
            "RFC 6923: MPLS Transport Profile (MPLS-TP) Identifiers
             Following ITU-T Conventions, May 2013, Section 7.1."
          DEFVAL {""}
          ::= { mplsOamIdMegEntry 6 }

















       mplsOamIdMegServicePointerType OBJECT-TYPE
          SYNTAX        INTEGER {
                            tunnel (1),
                            lsp (2),
                            pseudowire (3),
                            section (4)
                        }
          MAX-ACCESS    read-create
          STATUS        current
          DESCRIPTION
            "Indicates the service type for the MEG.
             If the service type indicates tunnel (1), the service
             pointer in the mplsOamIdMeTable points to an entry in
             the point-to-point mplsTunnelTable (RFC 3812).

             If the service type indicates lsp (2), the service pointer
             in the mplsOamIdMeTable points to an entry in
             the co-routed or associated bidirectional mplsTunnelTable.

             If the value is the pseudowire (3) service type, the
             service pointer in the mplsOamIdMeTable points to an entry
             in the pwTable (RFC 5601).

             If the value is the section (4) service type, the service
             pointer in the mplsOamIdMeTable points to an entry in
             the mplsTunnelTable (RFC 3812)."
          REFERENCE
            "1. RFC 3812: Multiprotocol Label Switching (MPLS)
                Traffic Engineering (TE) Management Information
                Base (MIB), June 2004.
             2. RFC 5601: Pseudowire (PW) Management Information
                Base (MIB), July 2009."
          DEFVAL { lsp }
          ::= { mplsOamIdMegEntry 7 }



















       mplsOamIdMegMpLocation OBJECT-TYPE
          SYNTAX        INTEGER {
                            perNode (1),
                            perInterface (2)
                        }
          MAX-ACCESS    read-create
          STATUS        current
          DESCRIPTION
            "Indicates the MP location type for this MEG.

             If the value is perNode, then the MEG in the LSR supports
             only perNode MEPs/MIPs, i.e., only one MEP/MIP in an LSR.

             If the value is perInterface, then the MEG in the LSR
             supports perInterface MEPs/MIPs, i.e., two MEPs/MIPs in
             an LSR."
          REFERENCE
            "RFC 6371: Operations, Administration, and Maintenance
             Framework for MPLS-Based Transport Networks,
             September 2011."
          DEFVAL { perNode }
          ::= { mplsOamIdMegEntry 8 }

       mplsOamIdMegPathFlow OBJECT-TYPE
          SYNTAX        INTEGER {
                            unidirectionalPointToPoint (1),
                            coRoutedBidirectionalPointToPoint (2),
                            associatedBidirectionalPointToPoint (3),
                            unidirectionalPointToMultiPoint (4)
                        }
          MAX-ACCESS    read-create
          STATUS        current
          DESCRIPTION
            "Indicates the transport path flow for this MEG.
             In the case of a unidirectional point-to-point transport
             path, a single unidirectional ME is defined to monitor it.
             In the case of associated bidirectional point-to-point
             transport paths, two independent unidirectional MEs are
             defined to independently monitor each direction.
             In the case of co-routed bidirectional point-to-point
             transport paths, a single bidirectional ME is defined to
             monitor both directions congruently.
             In the case of unidirectional point-to-multipoint transport
             paths, a single unidirectional ME for each leaf is defined
             to monitor the transport path from the root to that leaf."








          REFERENCE
            "RFC 6371: Operations, Administration, and Maintenance
             Framework for MPLS-Based Transport Networks,
             September 2011."
          DEFVAL { coRoutedBidirectionalPointToPoint }
          ::= { mplsOamIdMegEntry 9 }

       mplsOamIdMegOperStatus OBJECT-TYPE
          SYNTAX       INTEGER {
                           up (1),
                           down (2)
                       }
          MAX-ACCESS   read-only
          STATUS       current
          DESCRIPTION
            "This object specifies the operational status of the
             Maintenance Entity Group (MEG).  This object is used to
             send the notification to the SNMP manager about the MEG.

             The value up (1) indicates that the MEG and its monitored
             path are operationally up.  The value down (2) indicates
             that the MEG is operationally down.

             When the value of mplsOamIdMegOperStatus is up (1),
             all the bits of mplsOamIdMegSubOperStatus must be cleared.
             When the value of mplsOamIdMegOperStatus is down (2),
             at least one bit of mplsOamIdMegSubOperStatus must be set."
          ::= { mplsOamIdMegEntry 10 }

       mplsOamIdMegSubOperStatus OBJECT-TYPE
          SYNTAX       BITS {
                        megDown (0),
                        meDown (1),
                        oamAppDown (2),
                        pathDown (3)
                       }
          MAX-ACCESS   read-only
          STATUS       current
          DESCRIPTION
            "This object specifies the reason why the MEG operational
             status, as indicated by the object mplsOamIdMegOperStatus,
             is down.  This object is used to send the notification to
             the SNMP manager about the MEG.

             The bit 0 (megDown) indicates that the MEG is down.
             The bit 1 (meDown) indicates that the ME table is down.
             The bit 2 (oamAppDown) indicates that the OAM application
             (LSP or PW) monitored by this MEG is down.  Currently, BFD





             is the only supported OAM application.
             The bit 3 (pathDown) indicates that the underlying
             LSP or PW is down."
          ::= { mplsOamIdMegEntry 11 }

       mplsOamIdMegRowStatus OBJECT-TYPE
          SYNTAX        RowStatus
          MAX-ACCESS    read-create
          STATUS        current
          DESCRIPTION
             "This variable is used to create, modify, and/or delete
              a row in this table.  When a row in this table is in the
              active(1) state, no objects in that row can be modified
              by the agent except mplsOamIdMegRowStatus."
          ::= { mplsOamIdMegEntry 12 }

       mplsOamIdMegStorageType OBJECT-TYPE
          SYNTAX        StorageType
          MAX-ACCESS    read-create
          STATUS        current
          DESCRIPTION
            "This variable indicates the storage type for this
             object.
             Conceptual rows having the value 'permanent'
             need not allow write access to any columnar
             objects in the row."
          DEFVAL { volatile }
          ::= { mplsOamIdMegEntry 13 }

       -- End of MPLS Transport Profile MEG table


       -- Start of MPLS Transport Profile ME table

       mplsOamIdMeIndexNext OBJECT-TYPE
          SYNTAX        IndexIntegerNextFree (0..4294967295)
          MAX-ACCESS    read-only
          STATUS        current
          DESCRIPTION
            "This object contains an unused value for
             mplsOamIdMeIndex, or a zero to indicate
             that none exist.  Negative values are not allowed,
             as they do not correspond to valid values of
             mplsOamIdMeIndex."
          ::= { mplsOamIdObjects 3 }








       mplsOamIdMeMpIndexNext OBJECT-TYPE
          SYNTAX        IndexIntegerNextFree (0..4294967295)
          MAX-ACCESS    read-only
          STATUS        current
          DESCRIPTION
            "This object contains an unused value for
             mplsOamIdMeMpIndex, or a zero to indicate
             that none exist.  Negative values are not allowed,
             as they do not correspond to valid values of
             mplsOamIdMeMpIndex."
          ::= { mplsOamIdObjects 4 }

       mplsOamIdMeTable OBJECT-TYPE
          SYNTAX        SEQUENCE OF MplsOamIdMeEntry
          MAX-ACCESS    not-accessible
          STATUS        current
          DESCRIPTION
            "This table contains MPLS-TP ME information.

             The ME is some portion of a transport path that requires
             management bounded by two points (called MEPs), and the
             relationship between those points to which maintenance
             and monitoring operations apply.

             This table is generic enough to handle MEP and MIP
             information within a MEG."
          ::= { mplsOamIdObjects 5 }

       mplsOamIdMeEntry OBJECT-TYPE
          SYNTAX        MplsOamIdMeEntry
          MAX-ACCESS    not-accessible
          STATUS        current
          DESCRIPTION
            "An entry in this table represents an MPLS-TP ME.  This
             entry represents the ME if the source and sink MEPs are
             defined.

             An ME is a point-to-point entity.  One ME has two such
             MEPs.  A MEG is a group of one or more MEs.  One MEG can
             have two or more MEPs.

             For a point-to-point LSP, one MEG has one ME, and this ME
             is associated with two MEPs (source and sink MEPs) within
             a MEG.  Each mplsOamIdMeIndex value denotes the ME within
             a MEG.








             In the case of unidirectional point-to-point transport
             paths, a single unidirectional ME is defined to monitor
             it, and mplsOamIdMeServicePointer points to a
             unidirectional point-to-point path.

             In the case of associated bidirectional point-to-point
             transport paths, two independent unidirectional
             MEs are defined to independently monitor each direction,
             and each mplsOamIdMeServicePointer MIB object points to a
             unique unidirectional transport path.
             This has implications for transactions that terminate at
             or query a MIP, as a return path from a MIP to a source
             MEP does not necessarily exist within the MEG.

             In the case of co-routed bidirectional point-to-point
             transport paths, a single bidirectional ME is defined to
             monitor both directions congruently, and the
             mplsOamIdMeServicePointer MIB object points to a co-routed
             bidirectional point-to-point transport path.

             In the case of unidirectional point-to-multipoint transport
             paths, a single unidirectional ME for each leaf is defined
             to monitor the transport path from the root to that leaf,
             and each leaf has different transport path information in
             the mplsOamIdMeServicePointer MIB object.  Note that the
             MplsOamIdMeEntry should be created manually once the MEG
             is configured for OAM operations."
             INDEX { mplsOamIdMegIndex,
                     mplsOamIdMeIndex,
                     mplsOamIdMeMpIndex
                   }
             ::= { mplsOamIdMeTable 1 }

           MplsOamIdMeEntry ::= SEQUENCE {
              mplsOamIdMeIndex                  Unsigned32,
              mplsOamIdMeMpIndex                Unsigned32,
              mplsOamIdMeName                   SnmpAdminString,
              mplsOamIdMeMpIfIndex              InterfaceIndexOrZero,
              mplsOamIdMeSourceMepIndex         Unsigned32,
              mplsOamIdMeSinkMepIndex           Unsigned32,
              mplsOamIdMeMpType                 INTEGER,
              mplsOamIdMeMepDirection           INTEGER,
              mplsOamIdMeServicePointer         RowPointer,
              mplsOamIdMeRowStatus              RowStatus,
              mplsOamIdMeStorageType            StorageType
        }







       mplsOamIdMeIndex  OBJECT-TYPE
          SYNTAX        Unsigned32 (1..4294967295)
          MAX-ACCESS    not-accessible
          STATUS        current
          DESCRIPTION
            "Uniquely identifies an ME index within a MEG.  Managers
             should obtain new values for row creation in this table by
             reading mplsOamIdMeIndexNext."
          ::= { mplsOamIdMeEntry 1 }

       mplsOamIdMeMpIndex  OBJECT-TYPE
          SYNTAX        Unsigned32 (1..4294967295)
          MAX-ACCESS    not-accessible
          STATUS        current
          DESCRIPTION
            "Indicates the Maintenance Point (MP) index that is used to
             create multiple MEPs in a node of a single ME.  The value
             of this object can be the MEP index or the MIP index.
             Managers should obtain new values for row creation in this
             table by reading mplsOamIdMeMpIndexNext."
          ::= { mplsOamIdMeEntry 2 }

       mplsOamIdMeName  OBJECT-TYPE
          SYNTAX        SnmpAdminString (SIZE(1..48))
          MAX-ACCESS    read-create
          STATUS        current
          DESCRIPTION
            "This object denotes the ME name.  Each ME has a unique
             name within a MEG."
          ::= { mplsOamIdMeEntry 3 }

       mplsOamIdMeMpIfIndex OBJECT-TYPE
          SYNTAX        InterfaceIndexOrZero
          MAX-ACCESS    read-create
          STATUS        current
          DESCRIPTION
            "Indicates the MP interface.
             If the mplsOamIdMegMpLocation object value
             is perNode (1), the MP interface index should point
             to the incoming interface or outgoing interface, or
             be zero (to indicate that the MP OAM packets are initiated
             from the forwarding engine).

             If the mplsOamIdMegMpLocation object value is
             perInterface (2), the MP interface index should point to
             the incoming interface or outgoing interface."







          REFERENCE
            "1. RFC 6371: Operations, Administration, and Maintenance
                Framework for MPLS-Based Transport Networks,
                September 2011.
             2. RFC 2863: The Interfaces Group MIB, June 2000."
          DEFVAL { 0 }
          ::= { mplsOamIdMeEntry 4 }

       mplsOamIdMeSourceMepIndex  OBJECT-TYPE
          SYNTAX        Unsigned32
          MAX-ACCESS    read-create
          STATUS        current
          DESCRIPTION
            "Indicates the source MEP index of the ME.  This object
             should be configured if the mplsOamIdMegOperatorType object
             in the mplsOamIdMegEntry is configured as iccBased (2).
             If the MEG is configured for an IP-based operator,
             the value of this object should be set to zero, and the
             MEP ID will be automatically derived from the service
             identifiers (MPLS-TP LSP/PW Identifier)."
          DEFVAL { 0 }
          ::= { mplsOamIdMeEntry 5 }

       mplsOamIdMeSinkMepIndex  OBJECT-TYPE
          SYNTAX        Unsigned32
          MAX-ACCESS    read-create
          STATUS        current
          DESCRIPTION
            "Indicates the sink MEP index of the ME.  This object
             should be configured if the mplsOamIdMegOperatorType object
             in the mplsOamIdMegEntry is configured as iccBased (2).
             If the MEG is configured for an IP-based operator,
             the value of this object should be set to zero, and the
             MEP ID will be automatically derived from the service
             identifiers (MPLS-TP LSP/PW Identifier)."
          DEFVAL { 0 }
          ::= { mplsOamIdMeEntry 6 }
















       mplsOamIdMeMpType OBJECT-TYPE
          SYNTAX        INTEGER {
                            mep (1),
                            mip (2)
                        }
          MAX-ACCESS    read-create
          STATUS        current
          DESCRIPTION
            "Indicates the MP type within the MEG.

             The object should have the value mep (1) only in the
             ingress or egress nodes of the transport path.

             The object can have the value mip (2) in the
             intermediate nodes and possibly in the egress nodes
             of the transport path."
          DEFVAL { mep }
          ::= { mplsOamIdMeEntry 7 }

       mplsOamIdMeMepDirection OBJECT-TYPE
          SYNTAX        INTEGER {
                            up (1),
                            down (2),
                            notApplicable (3)
                        }
          MAX-ACCESS    read-create
          STATUS        current
          DESCRIPTION
            "Indicates the direction of the MEP.  This object
             should be configured if mplsOamIdMeMpType is configured
             as mep (1); otherwise, notApplicable (3) is set."
          DEFVAL { down }
          ::= { mplsOamIdMeEntry 8 }

       mplsOamIdMeServicePointer OBJECT-TYPE
          SYNTAX        RowPointer
          MAX-ACCESS    read-create
          STATUS        current
          DESCRIPTION
            "This variable represents a pointer to the MPLS-TP
             transport path.  This value MUST point at an entry in the
             mplsTunnelEntry if mplsOamIdMegServicePointerType
             is configured as tunnel (1), lsp (2), or section (4),
             or at an entry in the pwEntry if
             mplsOamIdMegServicePointerType is configured
             as pseudowire (3).







             Note: This service pointer object is placed in the ME table
             instead of the MEG table, since it will be useful in the
             point-to-multipoint case, where each ME will point to
             different branches of a point-to-multipoint tree."
          ::= { mplsOamIdMeEntry 9 }

       mplsOamIdMeRowStatus OBJECT-TYPE
          SYNTAX        RowStatus
          MAX-ACCESS    read-create
          STATUS        current
          DESCRIPTION
            "This variable is used to create, modify, and/or delete
             a row in this table.  When a row in this table is in the
             active(1) state, no objects in that row can be modified
             by the agent except mplsOamIdMeRowStatus."
          ::= { mplsOamIdMeEntry 10 }

       mplsOamIdMeStorageType OBJECT-TYPE
          SYNTAX        StorageType
          MAX-ACCESS    read-create
          STATUS        current
          DESCRIPTION
            "This variable indicates the storage type for this object.
             Conceptual rows having the value 'permanent'
             need not allow write access to any columnar
             objects in the row."
          DEFVAL { volatile }
          ::= { mplsOamIdMeEntry 11 }

       -- End of MPLS Transport Profile ME table

       -- End of MPLS-TP OAM tables





















   -- Notification definitions of MPLS-TP identifiers

       mplsOamIdDefectCondition NOTIFICATION-TYPE
          OBJECTS      {
                         mplsOamIdMegName,
                         mplsOamIdMeName,
                         mplsOamIdMegOperStatus,
                         mplsOamIdMegSubOperStatus
                       }
          STATUS       current
          DESCRIPTION
            "This notification is sent whenever the operational
             status of the MEG is changed."
          ::= { mplsOamIdNotifications 1 }

   -- End of notifications


   -- Module compliance

   mplsOamIdCompliances
      OBJECT IDENTIFIER ::= { mplsOamIdConformance 1 }

   mplsOamIdGroups
      OBJECT IDENTIFIER ::= { mplsOamIdConformance 2 }

   -- Compliance requirement for fully compliant implementations

   mplsOamIdModuleFullCompliance MODULE-COMPLIANCE
      STATUS       current
      DESCRIPTION "Compliance statement for agents that provide full
                   support for the MPLS-TP-OAM-STD-MIB.  Such devices
                   can then be monitored and also be configured
                   using this MIB module."

      MODULE IF-MIB -- The Interfaces Group MIB, RFC 2863
      MANDATORY-GROUPS {
         ifGeneralInformationGroup,
         ifCounterDiscontinuityGroup
      }

      MODULE -- this module
      MANDATORY-GROUPS {
            mplsOamIdMegGroup,
            mplsOamIdMeGroup
      }







      GROUP        mplsOamIdNotificationObjectsGroup
      DESCRIPTION "This group is only mandatory for those
                   implementations that can efficiently implement
                   the notifications contained in this group."

      GROUP        mplsOamIdNotificationGroup
      DESCRIPTION "This group is only mandatory for those
                   implementations that can efficiently implement
                   the notifications contained in this group."

      ::= { mplsOamIdCompliances 1 }

        -- Compliance requirement for read-only implementations

         mplsOamIdModuleReadOnlyCompliance MODULE-COMPLIANCE
            STATUS current
            DESCRIPTION
                "Compliance statement for agents that only provide
                 read-only support for the MPLS-TP-OAM-STD-MIB module."

            MODULE -- this module

         MANDATORY-GROUPS    {
            mplsOamIdMegGroup,
            mplsOamIdMeGroup
         }


      GROUP        mplsOamIdNotificationObjectsGroup
      DESCRIPTION "This group is only mandatory for those
                   implementations that can efficiently implement
                   the notifications contained in this group."

      GROUP        mplsOamIdNotificationGroup
      DESCRIPTION "This group is only mandatory for those
                   implementations that can efficiently implement
                   the notifications contained in this group."
















         -- mplsOamIdMegTable

         OBJECT      mplsOamIdMegName
         MIN-ACCESS  read-only
         DESCRIPTION
               "Write access is not required."

         OBJECT      mplsOamIdMegOperatorType
         MIN-ACCESS  read-only
         DESCRIPTION
               "Write access is not required."

         OBJECT      mplsOamIdMegIdCc
         MIN-ACCESS  read-only
         DESCRIPTION
               "Write access is not required."

         OBJECT      mplsOamIdMegIdIcc
         MIN-ACCESS  read-only
         DESCRIPTION
               "Write access is not required."

         OBJECT      mplsOamIdMegIdUmc
         MIN-ACCESS  read-only
         DESCRIPTION
               "Write access is not required."

         OBJECT      mplsOamIdMegServicePointerType
         MIN-ACCESS  read-only
         DESCRIPTION
               "Write access is not required."

         OBJECT      mplsOamIdMegMpLocation
         MIN-ACCESS  read-only
         DESCRIPTION
               "Write access is not required."

         OBJECT      mplsOamIdMegPathFlow
         MIN-ACCESS  read-only
         DESCRIPTION
               "Write access is not required."

         OBJECT      mplsOamIdMegRowStatus
         SYNTAX      RowStatus { active(1) }
         MIN-ACCESS  read-only
         DESCRIPTION
               "Write access is not required."






         OBJECT      mplsOamIdMegStorageType
         MIN-ACCESS  read-only
         DESCRIPTION
               "Write access is not required."

         -- mplsOamIdMeTable

         OBJECT      mplsOamIdMeName
         MIN-ACCESS  read-only
         DESCRIPTION
               "Write access is not required."

         OBJECT      mplsOamIdMeMpIfIndex
         MIN-ACCESS  read-only
         DESCRIPTION
               "Write access is not required."

         OBJECT      mplsOamIdMeSourceMepIndex
         MIN-ACCESS  read-only
         DESCRIPTION
               "Write access is not required."

         OBJECT      mplsOamIdMeSinkMepIndex
         MIN-ACCESS  read-only
         DESCRIPTION
               "Write access is not required."

         OBJECT      mplsOamIdMeMpType
         MIN-ACCESS  read-only
         DESCRIPTION
               "Write access is not required."

         OBJECT      mplsOamIdMeMepDirection
         MIN-ACCESS  read-only
         DESCRIPTION
               "Write access is not required."

         OBJECT      mplsOamIdMeServicePointer
         MIN-ACCESS  read-only
         DESCRIPTION
               "Write access is not required."

         OBJECT      mplsOamIdMeRowStatus
         SYNTAX      RowStatus { active(1) }
         MIN-ACCESS  read-only
         DESCRIPTION
               "Write access is not required."






         OBJECT      mplsOamIdMeStorageType
         MIN-ACCESS  read-only
         DESCRIPTION
               "Write access is not required."

      ::= { mplsOamIdCompliances 2 }

   -- Units of conformance

   mplsOamIdMegGroup OBJECT-GROUP
      OBJECTS {
         mplsOamIdMegIndexNext,
         mplsOamIdMegName,
         mplsOamIdMegOperatorType,
         mplsOamIdMegIdCc,
         mplsOamIdMegIdIcc,
         mplsOamIdMegIdUmc,
         mplsOamIdMegServicePointerType,
         mplsOamIdMegMpLocation,
         mplsOamIdMegOperStatus,
         mplsOamIdMegSubOperStatus,
         mplsOamIdMegPathFlow,
         mplsOamIdMegRowStatus,
         mplsOamIdMegStorageType
      }

      STATUS  current
      DESCRIPTION
            "Collection of objects needed for MPLS MEG information."
      ::= { mplsOamIdGroups 1 }























   mplsOamIdMeGroup  OBJECT-GROUP
      OBJECTS {
         mplsOamIdMeIndexNext,
         mplsOamIdMeMpIndexNext,
         mplsOamIdMeName,
         mplsOamIdMeMpIfIndex,
         mplsOamIdMeSourceMepIndex,
         mplsOamIdMeSinkMepIndex,
         mplsOamIdMeMpType,
         mplsOamIdMeMepDirection,
         mplsOamIdMeServicePointer,
         mplsOamIdMeRowStatus,
         mplsOamIdMeStorageType
      }
      STATUS  current
      DESCRIPTION
            "Collection of objects needed for MPLS ME information."
      ::= { mplsOamIdGroups 2 }

   mplsOamIdNotificationObjectsGroup  OBJECT-GROUP
      OBJECTS {
         mplsOamIdMegOperStatus,
         mplsOamIdMegSubOperStatus
      }
      STATUS  current
      DESCRIPTION
            "Collection of objects needed to implement notifications."
      ::= { mplsOamIdGroups 3 }

   mplsOamIdNotificationGroup NOTIFICATION-GROUP
      NOTIFICATIONS {
          mplsOamIdDefectCondition
      }
      STATUS  current
      DESCRIPTION
            "Set of notifications implemented in this module."
      ::= { mplsOamIdGroups 4 }

   END